Membrana repuesto Unger
zoom_out_map
chevron_left chevron_right

Unger RO M and L replacement membrane

Original Unger replacement reverse osmosis membrane for HydroPower RO M (RO35C) and RO40C systems. Sold individually — each system has 2 membranes, so 2 ROMEM units are required for a complete replacement. Replace when pure water production drops significantly or TDS does not improve after changing the resin cartridge. As Unger Technical Service in Spain, we diagnose and replace membranes. Reference ROMEM.

€493.23 VAT excluded

€493.23 VAT excluded

local_shipping ENVÍO GRATIS en pedidos de +75€ antes de IVA Sólo península (excepto en promos especiales informadas)

local_shipping ENVÍO EXPRÉS Realizamos nuestros envios mediante mensajería 24/48 horas. Algunos artículos pueden tener un plazo de entrega superior +INFO

⭐ With this product you earn 597 Limpieza Cristales Points

Unger ROMEM reverse osmosis membrane — original replacement for RO M (RO35C) and RO40C

The ROMEM membrane is the original replacement reverse osmosis membrane for Unger HydroPower RO M (RO35C) and RO40C systems. It is the central component of the osmosis system — the membrane that filters up to 98% of minerals from the water and determines the quality and flow rate of the pure water produced. Sold individually.

Important — 2 units are required to replace the equipment

Each RO M (RO35C) and RO40C system is fitted with 2 membranes. For a complete replacement of the system's membranes, you need to order 2 ROMEM units. If only one of the two membranes has deteriorated, it can be replaced individually — although it is usual to replace them as a pair to ensure balanced performance.

When should the membrane be replaced?

Significant drop in pure water flow rate — if the system produces less water than usual at the same inlet pressure, this may indicate membrane deterioration.

High TDS that does not improve after changing the resin cartridge — if the outlet TDS remains high after replacing the RORES resin filter, the problem may be with the membrane.

Chlorine damage — if the carbon pre-filter has not been replaced regularly, chlorine may have irreversibly damaged the membrane.

Diagnosis before replacement

Before ordering the membrane, we recommend calling us for a diagnosis. Membrane replacement is the most costly repair for the RO system — as Unger Technical Service in Spain, we confirm whether the problem is really the membrane or whether there is another cause before proceeding with the replacement.

Call us on 627 588 844 / 605 193 932.